Update on Building Products
informed Risk Manager Wendy Poulton offers a comprehensive update on the latest research and investigations on building product compliance in Australia.
Since the tragedy of the Grenfell Tower fire in London on 14 June 2017, developments in product compliance have sped up so quickly that it can be hard to keep pace with the latest thinking, and even harder to separate out official guidance from opinion and speculation.
At a recent forum by informed by Planned Cover in Melbourne, a room full of consultants discussed how their work has (and hasnāt) changed since June, and how they are responding to the challenges of specifying compliant products. The forum covered product failures ranging from shattering glass panels to bolt failures, asbestos and toxic mould and, of course, aluminium composite panel (ACP) cladding.
Overview of findings and investigations
To get the foundations right, we started with a recap of some recent findings:
- The Senate Committeeās recommended a ban on the import or use of polyethylene core ACPs, saying āthe committee does not consider there to be any legitimate use of PE core ACPs on any building typeā. However, noting the dissenting report by Coalition senators on the Committee, coupled with , itās by no means certain that this ban will in fact happen. Other useful recommendations from the report included national licensing for all participants in the construction industry, and making Australian Standards freely available.
- The WA Building Commissionās on Perth Childrenās Hospital found three types of ACP (Alpolic/FR, Alucobond Plus and Haidabond) to be compliant when used in limited quantity as sunshades or linings (none was used as a full-wall cladding system). The first two products came with CodeMark certification, but the builder and building surveyor were criticised for using Haidabond without obtaining appropriate certification. On the separate issue of unitised ceiling panels containing asbestos, findings of the were confirmed: although the builderās processes were ācomprehensive and consistent with industry practiceā, and required materials to be asbestos-free, the product was sourced through a complicated supply chain via an Australian subsidiary, Chinese parent company, and various suppliers within China, and no local testing was done once the product reached Australia.
- The Victorian Building Authority audit of around 170 buildings, published in February 2016, found 51% non-compliance, but only identified two buildings where cladding required an immediate emergency order. In Āé¶¹ŹÓʵ, an audit of 4,500 buildings identified 77 that āwarrant further investigationā, but so far none that immediately ārepresents a safety riskā.
- Ongoing investigations include the Victorian Cladding Taskforce, the and the .
- The Australian Building Codes Board is planning an out-of-cycle . Some key changes are requiring all wall elements to be non-combustible (including attachments, but not including a specified list of exclusions such as mandatory signs), and a new verification method for avoiding undue spread of fire up a faƧade (which is a combination of fire-rated panels tested to the new AS 5113:2016, balcony sprinklers and cavity barriers). Public comment closed in September 2017 and the changes, once finalised, are due to take effect in March 2018.
All of this reinforces the vital importance of clearly understanding the NCC requirements that apply to your building, and then either obtaining certification from manufacturers to confirm that their product meets the deemed-to-satisfy requirement, or having a robust paper trail showing the formal approval of a performance solution. When it comes to fire rating, advice may need to come from fire engineers as well as building surveyors/certifiers.
The way ahead
Drawing on the audienceās combined experience, our discussion forum identified some invaluable suggestions for achieving better results when it comes to building products.
Although it would be nice to think that Grenfell Tower has caused a revolution in the industry, and a new commitment to prioritising quality and compliance over cost outcomes, there was a feeling that the pressure to minimise costs has not been alleviated. However, there were reports of some lenders seeking to protect their investment by requiring assurances from principals and builders that the project is NCC-compliant. This may provide much-needed support for consultants championing better quality materials.
Noting that AS 1530.1 is inadequate for testing a full panel array, some alternatives suggested were AS 5113:2016, BS8414, NFPA 285, and EN 13501-1. For now, these alternative standards would require a properly documented and approved performance solution.
There were two final thoughts to come out of our discussion. First, that the current specific focus on ACPs glosses over accumulated risk caused by many other potentially combustible plastics and other products that form part of modern buildings. And second, even if using āfire ratedā ACPs with a substantial mineral content core, itās important to remember that these products can still burn. The from the Āé¶¹ŹÓʵ Advertiser provides a memorable illustration, and also highlights the superior performance of the āfire ratedā model.
Wendy Poulton is a risk manager atĢż.ĢżinformedĢżis the education and risk management arm of specialist insurance broker Planned Cover. Wendy and the team of legally qualified risk managers atĢżinformedĢżprovide online and live CPD, industry updates and guidance material, and deliver Planned Coverās contract review service.Ģż
Planned Cover is an ACA Corporate Sponsor.Ģż